Home & apartment load — single-phase 230 V / three-phase 400 V · breaker & cable sizing
System
Diversity < 1.0 if not all loads run at once. Length is used for voltage-drop estimate.
Loads
Apply to all:Set qty =Scale watts ×
Description
Watts each
Qty
Type
Total W
Tip: AC units, fridges, pumps and washing machines are motor loads — the tool adds a start-surge margin for them. Use the demand factor (below 1.0) because a home never runs every appliance at once.
Totals
–
Total connected watts
–
Total connected kW
–
Total connected amps
–
After diversity (kW)
–
After diversity (amps)
“Connected” = everything switched on at once (worst case). “After diversity” = realistic demand using your diversity factor — this is what the breaker & cable are sized on.
Three-phase balance — L1 / L2 / L3
–
L1 (Red)
–
L2 (Yellow)
–
L3 (Blue)
Each single-phase load is placed on the least-loaded phase for balance. Aim to keep the three phases within ~15% of each other so the neutral current stays low.
Results
–
Total load (after diversity)
–
Design current per phase
–
Suggested breaker
–
Suggested cable (Cu)
–
Voltage drop
Quick presets — load a whole home
Full plan — main load & DB schedule
–
Main connected load
–
Main current
–
Main breaker
–
Main incomer cable
–
Outgoing circuits
Each load line becomes one outgoing way from the DB, sized on its own (230 V circuit, 1.25× continuous). Main incomer sized on total after diversity. Distribute single-phase circuits evenly across L1/L2/L3 on three-phase supplies.
Live line — current passing
Animation speed & colour follow the calculated load vs breaker rating. Green <70%, amber 70–90%, red >90% of breaker.
Socket & ring circuit planner
Cable reference — all sizes (Cu)
Cable mm²
Ampacity (A)
Max MCB
Max length @3% drop
Ampacity is a conservative guide for Cu in conduit ~30 °C. Max length is for the current design current shown in Results, at 3% voltage drop. Derate for grouping, high ambient temperature, and insulation type per local regs.